- Other Lab Supplies[4]
- Measuring & Analysing Instrument Processing Services[10]
- Reactors[10]
- Other Measuring & Analysing Instruments[1]
- Spectrometers[7]
- Other Physical Measuring Instruments[2]
- Measuring & Analysing Instrument Stocks[6]
- Pumps[3]
- Other Machinery[1]
- Drying Equipment[9]
- Refrigeration & Heat Exchange Parts[2]
- Laboratory Thermostatic Devices[1]
- Clinical Analytical Instruments[7]
- Pipette[4]
- Ice Makers[9]
- Sterilization Equipments[3]
- Chemical Product Machinery[1]
- Contact Person : Ms. DUAN KATHY
- Company Name : Shaanxi Pengzhan Technology Co., Ltd.
- Tel : 86-187-29970929
- Fax : 86-29-82224225
- Address : Shaanxi,Xi'an,Room 1010,Sheng Du Mansion,Building 3 o,No.379,Electronic Road,Yanta District,Xi'an City
- Country/Region : China
- Zip : 710065
Related Product Searches:Atomic Absorption Spectrophotometer (Support GLP,GMP,high precision and sensitivity),High Quality,Atomic Absorption Spectrophotometer, spectrometer,PZ-1700
Atomic Absorption Spectrophotometer
Special FeaturesInside and outside aerosol -like the path ofrays integration structure and the CAN-BUS analysis system, guaranteed instrument's extendibility.Can install 10 hollow cathode lamps (possible to install two high performancehollow cathode lamp)The patent light signal processing system and high accuracy circuit design,ower electric noise, high antijamming ability Thermostable, anticorrosive entire titanium burner head, inertia polyphenylenesulfide atomizing chamber, had guaranteed easy to clean and the non-memoryeffect.
Intellectualized work software, realizes breakdown self-checking, as well as automaticbackground adjustment function.
Comprehensive security countermeasure, instrument exceptionally protects, acetylenerevelation warning, the undervoltage protection etc.
Technical Parameter ·wavelength scope: 190~900nm ·resolution <0.2nm
·wavelengthaccuracy :≤±0.2nm ·wavelength repeatability: ≤0.05nm
·static stability:≤0.001A/30min ·dynamic stability:≤0.003A/30min
·spectral bandwidth: 0.1,0.2,0.4,1.0nm
·background correction Deuterium Lamp Back-ground Corrention: At 1A≥50 Times
Self-ReversalBack-ground Corrention :At 1A≥50Times
Flame analysis;
·characteristicconcentration: 0.02μg/ml(Cu) ·limit of detection: 0.003μg/ml (Cu)
·RSD≤0.5%
·burner:metal entire titanium 50,100mm can switch burner
·The position adjustment optimum and around the position establishes automatically.
hyperthermia flame:Ba≥0.15 Abs
Graphite Furnace analysis;
·characteristicquantity Cd;0.3×10-12 g·limit of detection:Cd;0.2×10-12 g
·RSD:≤2%(Manual) ·Heating rate: ≥2000°C/s
·TemperatureRange:Ambient~3000°C ·Up to 9 steps with choices of ramp,temperature increase and full-power heating
·Control temperature way: dry cineration stage power control, atomization stage lightcontrols the maximum work rate elevation of temperature control
·Suit two types of pyrolytic graphite(Platform tube and non platform tube)
Graphite furnace Autosampler;
Intelligent sample configuration,automatic update of calibration data,matrix modification and automatic dilution of samples,self diagnosis function.
Maximumsampling volume:50µL,sampling accuracy1.0µL,RSD%≤1%
Sample Qty;s
Sample 50(2mL sample tray),high-capacity 5 (25mL sample tray)
Basic Parameters Mainframe
Dimensions;610×500×450[mm ](L× H× W) Weight;45Kg power ;150W
Power supply;AC 220V±22V 50HZ±0.5HZ
Graphite furnance system
Dimensions;240×500×450[mm ](L× H × W)
Weight;60KgPower;3600W
Power supply ;AC 220V±22V 50HZ±0.5HZ
Atomic Absorption Spectrophotometer (Support GLP,GMP,high precision and sensitivity)